Show simple item record

dc.contributor.authorChoubey, Bhaskaren_US
dc.contributor.authorJurcoane, Alinaen_US
dc.contributor.authorMuckli, Larsen_US
dc.contributor.authorSireteanu, Ruxandraen_US
dc.date.accessioned2012-01-11T00:40:40Z
dc.date.available2012-01-11T00:40:40Z
dc.date.copyright2009en_US
dc.date.issued2009-4-1en_US
dc.identifier.citationChoubey, Bhaskar, Alina Jurcoane, Lars Muckli, Ruxandra Sireteanu. "Methods for Dichoptic Stimulus Presentation in Functional Magnetic Resonance Imaging - A Review" The Open Neuroimaging Journal 3: 17-25. (2009)en_US
dc.identifier.issn1874-4400en_US
dc.identifier.urihttp://hdl.handle.net/2144/3037
dc.description.abstractDichoptic stimuli (different stimuli displayed to each eye) are increasingly being used in functional brain imaging experiments using visual stimulation. These studies include investigation into binocular rivalry, interocular information transfer, three-dimensional depth perception as well as impairments of the visual system like amblyopia and stereodeficiency. In this paper, we review various approaches of displaying dichoptic stimulus used in functional magnetic resonance imaging experiments. These include traditional approaches of using filters (red-green, red-blue, polarizing) with optical assemblies as well as newer approaches of using bi-screen goggles.en_US
dc.description.sponsorshipDeutsche Forschungsgemeinschaft (Si 344/17-1, 2, 3); University of Oxford.en_US
dc.language.isoenen_US
dc.publisherBentham Openen_US
dc.rightsCopyright Choubey et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.en_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc/3.0/en_US
dc.subjectDichoptic visual stimulationen_US
dc.subjectfMRIen_US
dc.subjectFiltersen_US
dc.subjectVideo gogglesen_US
dc.titleMethods for Dichoptic Stimulus Presentation in Functional Magnetic Resonance Imaging - A Reviewen_US
dc.typearticleen_US
dc.identifier.doi10.2174/1874440000903010017en_US
dc.identifier.pubmedid19526076en_US
dc.identifier.pmcid2695625en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Copyright Choubey et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
Except where otherwise noted, this item's license is described as Copyright Choubey et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.